| SUNSAVER | |||||||||
| SOLAR CONTROLLER | |||||||||
| Morningstar’s SunSaver is the world’s leading | Features: | ||||||||
| small solar controller for both professional and | |||||||||
| consumer applications. | • Eight versions available (see back) | ||||||||
| 12 and 24 volts | |||||||||
| SunSaver’s technology provides: | 6, 10 and 20 amps | ||||||||
| • Exceptional Reliability | • 100% solid state | ||||||||
| • PWM Battery Charging | • Series design (not shunt) | ||||||||
| • Consistent High Quality | • True 0 to 100% PWM duty cycle | ||||||||
| • Setpoint accuracy to 35 mV | |||||||||
| The SunSaver’s advanced design delivers | • Rated for 25% overloads | ||||||||
| outstanding performance and value. The | • Fully encapsulated in epoxy potting | ||||||||
| SunSaver’s low cost is made possible by | • Marine rated terminals/anodized case | ||||||||
| Morningstar’s unique approach to design | • Temperature compensation | ||||||||
| and manufacturing: | • Sealed/Flooded battery select | ||||||||
| • No need to derate | |||||||||
| • Automated production | • Parallel for 40 amps or more | ||||||||
| • Latest power electronic technologies | • Green charging/Red LVD indicators | ||||||||
| • Latest control and logic technologies | • Approved for use in hazardous locations - | ||||||||
| • High volume manufacturing | Class 1, Division 2, Groups A, B, C, D | ||||||||
| TECHNICAL SPECIFICATIONS | |||||||||
| SunSaver Model Selection Chart | |||||||||
| MODEL | SOLAR RATING (Amps) | LOAD RATING (Amps) | LVD | 12V | 24V | ||||
| NUMBER | 0 | 10 | 20 | 0 | 10 | 20 | |||
| • SS-6 | |||||||||
| • SS-6L | |||||||||
| • SS-10 | |||||||||
| • SS-10L | |||||||||
| • SS-10-24V | |||||||||
| • SS-10L-24V | |||||||||
| • SS-20L | |||||||||
| • SS-20L-24V | |||||||||
| Electrical Specifications | 12 Volts | 24 Volts | Mechanical Specifications | ||||||
| Rated Solar Input | 6.5 /10/20 A | Wire size #10 AWG (5.2 mm2) | |||||||
| Rated Load | 6/10/20 A | Anodized aluminum case | |||||||
| 25% Current Overload | 5 min. | 5 min. | Marine rated terminals | ||||||
| Regulation Voltage: | Epoxy encapsulated | ||||||||
| Sealed Battery | 14.1 V | 28.2 V | Weight is 8 oz (0.23 kg) | ||||||
| Flooded Battery | 14.4 V | 28.8 V | |||||||
| Load Disconnect | 11.5 V | 23.0 V | |||||||
| LVD Reconnect | 12.6 V | 25.2 V | |||||||
| Temp. Comp. (mV/˚C) | -28 | -56 | |||||||
| Self-consumption | 6 to 10 mA | ||||||||
| Operating Temp. | -40 to +85ºC | ||||||||
| Warranty: Five year warranty period. Contact Morningstar or your authorized distributor for complete terms. | |||||||||
| E112204 | |||||||||
| For Use In Cl I, Div 2, Gp ABCD | |||||||||
| Hazardous Locations Voc =13.5Vdc | |||||||||
| UL1604 CSA 22.2 No. 213-M1987 | |||||||||