| SUNNY BOY 8000-US | ||
| Versatile performer with UL certification | ||
| The Sunny Boy 5000-US, 6000-US, 7000-US and 8000-US inverters are UL certified and feature excellent efficiency. Graduated power classes provide flexibility in system design. Automatic grid voltage detection* and an integrated DC disconnect switch simplify installation, ensuring safety as well as saving time. These models feature galvanic isolation and can be used with all types of modules—crystalline as well as thin-film. | ||
| * US Patent US7352549B1 | ||
| Technical data | Sunny Boy 8000-US | |
| 240 V AC | 277 V AC | |
| Input (DC) | ||
| Max. recommended PV power (@ module STC) | 10000 W | |
| Max. DC power (@ cos ϕ = 1) | 8600 W | |
| Max. DC voltage | 600 V | |
| DC nominal voltage | 345 V | |
| MPP voltage range | 300 V - 480 V | |
| Min. DC voltage / start voltage | 300 V / 365 V | |
| Max. input current / per string (at DC disconnect) | 30 A / 20 A | |
| 36 A @ combined terminal | ||
| Number of MPP trackers / | 1 / 4 (DC disconnect) | |
| fused strings per MPP tracker | ||
| Output (AC) | ||
| AC nominal power | 7680 W | 8000 W |
| Max. AC apparent power | 8000 VA | |
| Nominal AC voltage / adjustable | 240 V / ● | 277 V / ● |
| AC voltage range | 211 - 264 V | 244 - 305 V |
| AC grid frequency; range | 60 Hz; 59.3 - 60.5 Hz | |
| Max. output current | 32 A | |
| Power factor (cos ϕ) | 1 | |
| Phase conductors / connection phases | 1 / 2 | 1 / 1 |
| Harmonics | < 4% | |
| Efficiency | ||
| Max. efficiency | 96.30% | 96.50% |
| CEC efficiency | 96.00% | 96.00% |
| Protection devices | ||
| DC reverse-polarity protection | ● | |
| AC short circuit protection | ● | |
| Galvanically isolated / all-pole sensitive monitoring unit | ●/— | |
| Protection class / overvoltage category | I / III | |
| General data | ||
| Dimensions (W / H / D) in mm (in) | 470 / 615 / 240(18.5 / 24 / 9) | |
| DC Disconnect dimensions (W / H / D) in mm (in) | 187 / 297 / 190(7 / 12 / 7.5) | |
| Packing dimensions (W / H / D) in mm (in) | 390 / 580 / 800(16 / 23 / 31.5) | |
| DC Disconnect packing dimensions (W / H / D) in mm (in) | 370 / 240 / 280(15 / 9 / 11) | |
| Weight / DC Disconnect weight | 66 kg (145 lb) / 3.5 kg (8 lb) | |
| Packing weight / DC Disconnect packing weight | 69 kg (152 lb) / 4 kg (9 lb) | |
| Operating temperature range (full power) | -25 °C ... +45 °C(-13 °F ... +113 °F) | |
| Noise emission (typical) | 49 dB(A) | |
| Internal consumption at night | 0.1 W | |
| Topology | LF transformer | |
| Cooling concept | OptiCool | |
| Electronics protection rating / connection area | NEMA 3R / NEMA 3R | |
| Features | ||
| Display: text line / graphic | ●/— | |
| Interfaces: RS485 / Bluetooth | ○/○ | |
| Warranty: 10 / 15 / 20 years | ●/○/○ | |
| Certificates and permits (more available on request) | UL1741, UL1998, IEEE 1547, FCC Part 15 (Class A & B). CSA C22.2 No. 107.1-2001 | |
| NOTE: US inverters ship with gray lids. | ||
| Data at nominal conditions | ||
| ● Standard features ○ Optional features — Not available | ||
| Type designation | SB 8000US | |
| Toll Free +1 888 4 SMA USA | ||
| www.SMA-America.com | SMA America, LLC | |