| Pro Star SOLAR CONTROLLER | ||||
| Morningstars ProStar is the worlds leading | Tropicalization: conformal coating, stainless- | |||
| mid-range solar controller for both professional | steel fasteners & anodized aluminum heat sink | |||
| and consumer applications. This second | No switching or measurement in the grounded leg | |||
| generation ProStar: | 100% solid state | |||
| Adds new features and protections using | Very low voltage drops | |||
| highly advanced technology | Current compensated low voltage | |||
| Provides longer battery life and improved | disconnect (LVD) | |||
| system performance | LEDs indicate battery status and faults | |||
| Sets new standards for reliability and | Capable of 25% overloads | |||
| self-diagostics | Remote battery voltage sense terminals | |||
| Standard Features: | Electronic Protections: | |||
| Versions available: 15 or 30 amp | ||||
| 12 / 24 or 48 volt | Short-circuit solar and load | |||
| negative or positive ground | Overload solar and load | |||
| Estimated 15 year life | Reverse polarity | |||
| PWM series battery charging (not shunt) | Reverse current at night | |||
| 3-position battery select: gel, sealed | High voltage disconnect | |||
| or flooded | High temperature disconnect | |||
| Very accurate control and measurement | Lightning and transient surge protection | |||
| Jumper to eliminate telecom noise | Loads protected from voltage spikes | |||
| Parallel for up to 300 amps | Automatic recovery with all protections | |||
| Temperature compensation | ||||
| TECHNICAL SPECIFICATIONS | ||||
| ProStar Options: | ProStar Versions: | |||
| Digital meter | PS-15 | PS-30 | PS15M-48V | |
| - Highly accurate voltage and current display | Rated Solar Current | 15A | 30A | 15A |
| - Low self-consumption (1 mA) | Rated Load Current | 15A | 30A | 15A |
| - Includes manual disconnect button | System Voltage | 12/24V | 12/24V | 48V |
| - Displays 5 different protection functions | Options: | |||
| and disconnect conditions | Digital Meter | yes | yes | standard |
| - Self-Diagnostics (self-test) provides a | Positive Ground | no | yes | yes |
| comprehensive test of the ProStar | Remote Temp. Probe | yes | yes | yes |
| Displays 9 different controller status | ||||
| parameters, including temperature | ||||
| Displays detected faults | Battery Voltage Setpoints* | |||
| Positive ground | Gel | Sealed | Flooded | |
| Remote temperature probe | Regulation Voltage | 14.0 | 14.15 | 14.4 |
| Float | 13.7 | 13.7 | 13.7 | |
| Optimized Battery Charging: | Equalization | n/a | 14.35 | 14.9/15.1 |
| The ProStar has 4 stages of charging to provide | Load Disconnect | 11.4 | 11.4 | 11.4 |
| increased battery capacity and life. | Load Reconnect | 12.6 | 12.6 | 12.6 |
| Note: values are for 12V. Use 2X for 24V and 4X for 48V. | ||||
| Electrical Specifications: | ||||
| 12V | 24V | 48V | ||
| Temp. Comp. (mV/˚C)* | - 30mV | - 60mV | - 120mV | |
| Accuracy | 40mV | 60mV | 80mV | |
| Min. voltage to operate | 8V | 8V | 15V | |
| Self Consumption | 22mA | 25mA | 28mA | |
| LVD current coefficient** | - 20mV | - 40mV | - 80mV | |
| Charge algorithm | PWM, constant voltage | |||
| Operating temperature | - 40˚C to + 60˚C | |||
| Digital Display: | ||||
| Operating temperature | - 30˚C to + 85˚C | |||
| Voltage accuracy | 0.50% | |||
| Current accuracy | 2.00% | |||
| Self-consumption | 1 mA | |||
| * 25˚C reference | ||||
| ** per amp of load | ||||
| WARRANTY: Five year warranty period. Contact Morningstar or your authorized distributor for complete terms. | ||||