Fronius IG Plus PV Inverter |
|
| |
The first complete solution. Reliable. Proven. Smart. |
|
| |
INPUT DATA |
Fronius IG Plus V |
7.5-1 UNI |
|
| |
Recommended PV-Power (Wp) |
6350-8600 |
|
| |
MPPT-Voltage Range |
230 ... 500 V |
|
| |
DC Startup Voltage |
245 V |
|
| |
Max. Input Voltage (at 1000 W/m² |
600 V |
|
| |
14°F (-10°C) in open circuit operation) |
|
| |
Nominal Input Current |
20.7 A |
|
| |
Max. usable Input Current |
35.1 A |
|
| |
Admissible conductor size (DC) |
No. 14 - 6 AWG |
|
| |
Number of DC Input Terminals |
6 |
|
| |
Max. Current per DC Input Terminal |
20 A; Bus bar available for higher input currents |
|
| |
OUTPUT DATA |
Fronius IG Plus V |
7.5-1 UNI |
|
| |
Nominal output power (PAC nom) |
7500 W |
|
| |
Max. continuous output power
104°F(40°C)208V/240V/277V |
7500 W |
|
| |
Nominal AC output voltage |
208 V / 240 V / 277 V |
|
| |
Operating AC voltage
rangeDefault |
208 V |
183 - 229 V (-12 / +10 %) |
|
| |
240 V |
211 - 264 V (-12 / +10 %) |
|
| |
277 V |
244 - 305 V (-12 / +10 %) |
|
| |
Max. continuous output
current |
208 V |
36.1 A |
|
| |
240 V |
31.3 A |
|
| |
277 V |
27.1 A |
|
| |
Admissible
conductor size (AC) |
|
No. 14 - 4 AWG |
|
| |
Max.
continuous utility back feed current |
|
0A |
|
| |
Nominal output
frequency |
|
60 Hz |
|
| |
Operating
frequency range |
|
59.3 - 60.5 Hz |
|
| |
Total harmonic
distortion |
|
< 3 % |
|
| |
Power factor |
|
1 |
|
| |
GENERAL DATA |
Fronius IG Plus V |
7.5-1 UNI |
|
| |
Max.
Efficiency |
|
0.962 |
|
| |
CEC Efficiency |
208 V |
0.95 |
|
| |
240 V |
0.955 |
|
| |
277 V |
0.96 |
|
| |
Consumption in
standby (night) |
|
< 1.5 W |
|
| |
Consumption
during operation |
|
14 W |
|
| |
Cooling |
|
Controlled forced ventilation, variable fan speed |
|
| |
Enclosure Type |
|
NEMA 3R |
|
| |
Unit
Dimensions (W x H x D) |
|
17.1 x 38.1 x 9.9 in. |
|
| |
Power Stack
Weight |
|
57 Ibs. (26 kg) |
|
| |
Wiring
Compartment Weight |
|
26 Ibs. (12 kg) |
|
| |
Admissible
ambient operating temperature |
|
-4 ... 122ºF (-20 ... +55ºC) |
|
| |
Compliance |
|
UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, ANSI/IEEE C62.41, FCC
Part 15 A& B, NEC Article 690, C22. 2 No. 107.1-01 (Sept. 2001) |
|
| |
PROTECTION DEVICES |
Fronius IG Plus V |
7.5-1 UNI |
|
| |
Ground fault
protection |
|
Internal GFDI (Ground Fault Detector/Interrupter); in accordance
with UL 1741-2010 and NEC Art. 690 |
|
| |
DC reverse
polarity protection |
|
Internal diode |
|
| |
Islanding
protection |
|
Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and
NEC |
|
| |
Over
temperature |
|
Output power derating / active cooling |
|
| |
* per Phase |
|
|
|
| |
|
|
|
|
| |
An
outstanding addition to the family: The next generation Fronius IG Plus
inverter builds on a successful model with multiple enhancements, including
maximum power harvest, a built-in six circuit string combiner, integrated,
lockable DC Disconnect, significantly improved efficiency, and unbeatable
reliability. New, larger power stages expand the proven Fronius IG family
from 2 to 12 kW in a single inverter. |
|
|
|
|
|
|