FRONIUS
IG |
|
| |
GRID-TIED INVERTERS FOR
PHOTOVOLTAIC SYSTEMS |
|
| |
|
|
|
| |
Light Weight |
At 42 lbs, the FRONIUS IG inverters
are the lightest grid-connected inverters making them both easy and
cost-effective to install. |
|
| |
|
| |
More Energy |
MIXTM
Concept allows your system to output more energy under part-load
conditions. |
|
| |
|
| |
Lower Cost |
Integrated UL approved DC & AC
disconnects which reduce installation time and complexity - often eliminating
the need for additional disconnects. |
|
| |
|
| |
LCD Display |
User-friendly and comes standard with
every FRONIUS IG; tracks more than 20 critical system performance parameters. |
|
| |
|
| |
Powerful |
At 4000, 4500 and 5100 watts, these
inverters deliver more power output for higher performance installations. |
|
| |
|
| |
Reliable |
Fronius has been in business for over
60 years and has more than 200,000 FRONIUS IG inverters installed worldwide. |
|
| |
|
| |
Warranty |
10
year Premium Warranty. |
|
| |
|
|
|
| |
FRONIUS IG |
|
| |
FRONIUS IG 4000 Specifications |
|
| |
DC
Input Data |
FRONIUS IG 4000 |
|
| |
Recommended
PV power |
3000 - 5000 Wp |
|
| |
Max.
DC input voltage |
500 V |
|
| |
Operating
DC voltage range |
150 - 450 V |
|
| |
Max.
usable DC input current |
26.1 A |
|
| |
AC Output Data |
FRONIUS IG
4000 |
|
| |
Maximum
output power @40° C |
4000 W |
|
| |
Nominal
AC output voltage |
240 V |
|
| |
Utility
AC voltage range |
212 - 264 V (240 V +10% / -12%) |
|
| |
Maximum
AC current |
16.7 A |
|
| |
Maximum
utility back feed current |
0.0 A |
|
| |
Operating
frequency range |
59.3 - 60.5 Hz (60 Hz nom) |
|
| |
Total
harmonic distortion |
< 5 % |
|
| |
Power
Factor (cos phi) |
1 |
|
| |
General Data |
FRONIUS IG
4000 |
|
| |
Max.
efficiency |
0.952 |
|
| |
Consumption
in stand-by |
< 0.15 W (night) |
|
| |
Consumption
during operation |
15 W |
|
| |
Enclosure |
NEMA 3R |
|
| |
Size
(l x w x h) |
28.4 x 16.5 x 8.8 in (720 x 418 x 223
mm) |
|
| |
Weight |
42 lbs. (19 kg) |
|
| |
Ambient
temperature range |
-5 to 122 °F (-20 to +50 °C) |
|
| |
Cooling |
controlled forced ventilation |
|
| |
Integrated
DC and AC disconnects |
standard UL approved DC & AC
disconnects |
|
| |
Protections |
|
|
| |
Ground
fault protection |
Internal GFDI, in accordance with UL
1741 |
|
| |
DC
reverse polarity protection |
Internal diode |
|
| |
Islanding
protection |
Internal, in accordance with UL 1741,
IEEE 1547 |
|
| |
Over
temperature |
Output power derating |
|
| |
Surge
Protection |
Internal DC & AC protection, Tested
to 6 kV |
|
| |
Compliance |
|
|
| |
Safety |
UL 1741 |
|
| |
EMI |
FCC Part 15; Class A & B |
|
| |
Anti-Islanding
protection |
UL 1741, IEEE 1547 |
|
| |
Ground
fault detector and interrupter |
Compliant with NEC Art. 690
requirements, UL 1741 |
|
| |
Miscellaneous |
|
|
| |
Maximum
AC over current protection |
Two-pole, 30 A circuit breaker |
|
| |
AC
wire sizing |
Use maximum AWG 6 194°F (90 °C) copper
wire |
|
| |
DC
wire sizing |
Use maximum AWG 6 194°F (90 °C) copper
wire |
|
| |
AC
disconnect |
32 A |
|
| |
DC
disconnect |
40 A |
|
| |
Warranty |
10 year Premium Warranty is Standard |
|
| |
|
|
|
|
|
|
|